{"id":14194,"date":"2021-03-26T13:25:02","date_gmt":"2021-03-26T18:25:02","guid":{"rendered":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/\/?p=14194"},"modified":"2025-05-23T08:15:58","modified_gmt":"2025-05-23T13:15:58","slug":"temperature-compensated-gas-density-monitors-accurately-measures-sf6","status":"publish","type":"post","link":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/knowhow\/temperature-compensated-gas-density-monitors-accurately-measures-sf6\/","title":{"rendered":"Measure SF6: Temperature-Compensated Gas Density Monitors"},"content":{"rendered":"<p><strong>WIKA offers a complete range of gas density monitors to accurately measure sulfur hexafluoride (SF<sub>6<\/sub>) and other gases. Our temperature-compensated gas density solutions use one of four types of pressure sensing technologies: bimetal, bellow, reference chamber, and electronic sensing with Wheatstone bridge.<\/strong><\/p>\n<p>Smart monitoring systems use a <a href=\"https:\/\/blog-stage.wika.cloudpowered.services\/us\/\/applications\/electronic-pressure-sensors-predictive-maintenance-2\/\">condition-based approach<\/a> \u2013 repair or replace something only when the need arises \u2013 rather than relying on just preventive or reactive maintenance. The online monitoring of SF<sub>6<\/sub> gas with trend analysis reduces the risk of failure and lowers operating costs by using such a condition-based strategy. No more unnecessary work within defined maintenance cycles. Fewer service calls to rectify faults. Less plant downtime. Higher profit margins.<\/p>\n<p>Using a gas density monitor also means faster turnaround times and greater safety. If the system warns of a leak, technicians can use a portable SF<sub>6<\/sub> detector to quickly determine the exact location of the damaged switchgear, line, or transformer, and then repair it. An online system makes the process even easier by giving a visual of the leak\u2019s location.<\/p>\n<p>Power plants and T&amp;D equipment are exposed to all sorts of weather, including extreme temperatures, high humidity, strong winds, and sudden changes in ambient pressure. Our products for SF<sub>6<\/sub> gas density monitoring are solid, built to withstand harsh conditions and provide many years of reliable service.<\/p>\n<h2>Gas Density &amp; Temperature Compensation<\/h2>\n<p>A common application issue when it comes to gas measuring instruments is temperature compensation.\u00a0At a constant volume, the pressure of an ideal gas increases proportionally with temperature. This is Gay-Lussac\u2019s law. Therefore, <a href=\"https:\/\/blog-stage.wika.cloudpowered.services\/us\/\/products\/sf6-products\/gas-temperature-affect-gas-density-measurements\/\">any change in the ambient temperature will mean a similar change in the pressure<\/a> (Figure 1), even though the gas density remains constant. To determine the actual gas density, a pressure measuring instrument must take into account \u2013 or compensate for \u2013 variations in temperature (Figure 2). The result is the temperature-compensate pressure (Figure 3), a displayed value that corresponds to the actual gas density.<\/p>\n\n      <div class=\"wp-caption aligncenter\" style=\"max-width:846px;\"><img decoding=\"async\" src=\"https:\/\/blog-stage.wika.cloudpowered.services\/us\/\/files\/2021\/03\/temperature-compensation-fig.-1-3-838x199.png\" alt=\"Temperature compensation\" \/><p class=\"wp-caption-text\">Temperature compensation of gas measuring instruments<\/p><\/div>\n    \n<h2>\n4 Types of Temperature-Compensated Gas Density Monitors<\/h2>\n<p>WEgrid Products offers several types of temperature-compensated <a href=\"https:\/\/www.wika.com\/en-us\/gas_density_monitors.WIKA\" rel=\"external\" target=\"_blank\">gas density monitors<\/a> and gas density indicators.<\/p>\n<ul>\n<li>\n\n      <div class=\"wp-caption alignright\" style=\"max-width:308px;\"><img loading=\"lazy\" decoding=\"async\" class=\"size-ArticleFeatured wp-image-14201\" src=\"https:\/\/blog-stage.wika.cloudpowered.services\/us\/\/files\/2021\/03\/gdm_100.png\" alt=\"GDM-100-TI-D\" width=\"300\" height=\"245\" srcset=\"https:\/\/blog-stage.wika.cloudpowered.services\/us\/files\/2021\/03\/gdm_100.png 300w, https:\/\/blog-stage.wika.cloudpowered.services\/us\/files\/2021\/03\/gdm_100-184x150.png 184w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><p class=\"wp-caption-text\">GDM-100-TI-D gas density monitor with Modbus output<\/p><\/div>\n    <br \/>\n<strong>Bimetal: Gas density monitor and indicator <\/strong>\u2014 A bimetallic strip between the movement and the measuring tube converts changes in temperature into changes in length. The indication on the dial is constant, despite the temperature-induced pressure variations. Only declining pressure due to loss of gas is displayed.<\/li>\n<li><strong>Metal bellows: Gas density monitor with external temperature probe <\/strong>\u2014 The temperature compensation with external capillary sensor enables temperature measurement directly in the SF<sub>6<\/sub> gas tank.<\/li>\n<li><strong style=\"font-size: 1rem\">Reference chamber: <a href=\"https:\/\/www.wika.com\/en-us\/gas_density_switches.WIKA\" rel=\"external\" target=\"_blank\">Gas density switch <\/a><\/strong><span style=\"font-size: 1rem\">\u2014 In WIKA\u2019s gas density switches, a compartment filled with pure SF<\/span><sub>6<\/sub><span style=\"font-size: 1rem\"> serves as the benchmark. A stainless steel sensor measures the density of the gas inside medium- or high-voltage equipment, and compares it against the gas inside the reference chamber. If the equipment\u2019s gas density drops to a specified level, the switch sends out a warning. Since the switch is hermetically sealed, the reference gas is impervious to variations in ambient temperature or atmospheric pressure. The result: No fluctuations in the measured value, and no false alarms caused by environmental changes. In addition, having a reference chamber means these switches do not require recalibration.<\/span><\/li>\n<li><strong style=\"font-size: 1rem\">Electronic sensor: Gas density transmitter <\/strong><span style=\"font-size: 1rem\">\u2014 A pressure transmitter specially developed for measuring SF<\/span><sub>6<\/sub><span style=\"font-size: 1rem\"> density delivers a temperature-compensated output signal. Its electronic sensor uses a <\/span><a style=\"font-size: 1rem;background-color: #ffffff\" href=\"https:\/\/blog-stage.wika.cloudpowered.services\/us\/\/applications\/electronic-instrumentation-for-safe-and-reliable-pressure-measurements-in-high-pressure-applications\/\">Wheatstone bridge<\/a><span style=\"font-size: 1rem\"> to detect the pressure and temperature of the SF<\/span><sub>6<\/sub><span style=\"font-size: 1rem\"> inside gas-insulated equipment, and then uses an electronic evaluation system to accurately calculate the current gas density. For even greater protection against ambient temperatures and pressures, the stainless steel transmitter is hermetically sealed and fully welded.<\/span><\/li>\n<\/ul>\n<p>WEgrid Products has an <a href=\"https:\/\/www.wika.com\/en-us\/power_transmission_and_distribution_sf6.WIKA?tab=3\" rel=\"external\" target=\"_blank\">extensive portfolio of modular instruments<\/a> specifically designed and optimized for monitoring SF<sub>6<\/sub> gas density in medium- and high-voltage equipment. Customers have their choice of mechanical\/mechatronic and electronic instruments with various accuracies, measuring ranges, output signals, alarm functionalities, and other features. Contact our SF<sub>6<\/sub> specialists for more information about <a href=\"https:\/\/www.wika.com\/en-us\/power_transmission_and_distribution_sf6.WIKA?tab=1\" rel=\"external\" target=\"_blank\">industrial SF<sub>6<\/sub> gas handling<\/a>.<\/p>\n<p>[contact-form-7 id=&#8221;14552&#8243; title=&#8221;Blog Contact Form&#8221;]<\/p>\n<div style=\"width: 100%;float: left\"><a class=\"button white\" style=\"float: right\" href=\"https:\/\/www.wika.com\/en-us\/contact.WIKA\" rel=\"external\" target=\"_blank\"><span>Contact us<\/span><\/a><\/div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>WIKA offers a complete range of gas density monitors to accurately measure sulfur hexafluoride (SF6) and other gases. Our temperature-compensated gas density solutions use one of four types of pressure sensing technologies: bimetal, bellow, reference chamber, and electronic sensing with Wheatstone bridge. Smart monitoring systems use a condition-based approach \u2013 repair or replace something only [&hellip;]<\/p>\n","protected":false},"author":189,"featured_media":14203,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[5,674],"tags":[677],"class_list":["post-14194","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowhow","category-sf6-products","tag-sf6"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Measure SF6: 4 Types of Gas Density Monitors - WIKA blog<\/title>\n<meta name=\"description\" content=\"WIKA offers a complete range of temperature-compensated gas density monitors to accurately measure sulfur hexafluoride (SF6) and other gases.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog-stage.wika.cloudpowered.services\/us\/knowhow\/temperature-compensated-gas-density-monitors-accurately-measures-sf6\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Measure SF6: 4 Types of Gas Density Monitors - WIKA blog\" \/>\n<meta property=\"og:description\" content=\"WIKA offers a complete range of temperature-compensated gas density monitors to accurately measure sulfur hexafluoride (SF6) and other gases.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog-stage.wika.cloudpowered.services\/us\/knowhow\/temperature-compensated-gas-density-monitors-accurately-measures-sf6\/\" \/>\n<meta property=\"og:site_name\" content=\"WIKA blog\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog-stage.wika.cloudpowered.services\/us\/files\/2021\/03\/wika_hochspannung_istock_935697medium_cmyk_resized.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"838\" \/>\n\t<meta property=\"og:image:height\" content=\"471\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Leo Lopez\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Leo Lopez\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/knowhow\\\/temperature-compensated-gas-density-monitors-accurately-measures-sf6\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/knowhow\\\/temperature-compensated-gas-density-monitors-accurately-measures-sf6\\\/\"},\"author\":{\"name\":\"Leo Lopez\",\"@id\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/#\\\/schema\\\/person\\\/2a70a7718e6bfe7c6052a7702d4057c5\"},\"headline\":\"Measure SF6: Temperature-Compensated Gas Density Monitors\",\"datePublished\":\"2021-03-26T18:25:02+00:00\",\"dateModified\":\"2025-05-23T13:15:58+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/knowhow\\\/temperature-compensated-gas-density-monitors-accurately-measures-sf6\\\/\"},\"wordCount\":693,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/knowhow\\\/temperature-compensated-gas-density-monitors-accurately-measures-sf6\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/files\\\/2021\\\/03\\\/wika_hochspannung_istock_935697medium_cmyk_resized.jpg\",\"keywords\":[\"SF6\"],\"articleSection\":[\"Know-how\",\"SF6 Gas Solutions\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/knowhow\\\/temperature-compensated-gas-density-monitors-accurately-measures-sf6\\\/\",\"url\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/knowhow\\\/temperature-compensated-gas-density-monitors-accurately-measures-sf6\\\/\",\"name\":\"Measure SF6: 4 Types of Gas Density Monitors - WIKA blog\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/knowhow\\\/temperature-compensated-gas-density-monitors-accurately-measures-sf6\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/knowhow\\\/temperature-compensated-gas-density-monitors-accurately-measures-sf6\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/files\\\/2021\\\/03\\\/wika_hochspannung_istock_935697medium_cmyk_resized.jpg\",\"datePublished\":\"2021-03-26T18:25:02+00:00\",\"dateModified\":\"2025-05-23T13:15:58+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/#\\\/schema\\\/person\\\/2a70a7718e6bfe7c6052a7702d4057c5\"},\"description\":\"WIKA offers a complete range of temperature-compensated gas density monitors to accurately measure sulfur hexafluoride (SF6) and other gases.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/knowhow\\\/temperature-compensated-gas-density-monitors-accurately-measures-sf6\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/knowhow\\\/temperature-compensated-gas-density-monitors-accurately-measures-sf6\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/knowhow\\\/temperature-compensated-gas-density-monitors-accurately-measures-sf6\\\/#primaryimage\",\"url\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/files\\\/2021\\\/03\\\/wika_hochspannung_istock_935697medium_cmyk_resized.jpg\",\"contentUrl\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/files\\\/2021\\\/03\\\/wika_hochspannung_istock_935697medium_cmyk_resized.jpg\",\"width\":838,\"height\":471,\"caption\":\"WIKA offers a complete range of gas density monitors to accurately measure sulfur hexafluoride (SF6) and other gases.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/knowhow\\\/temperature-compensated-gas-density-monitors-accurately-measures-sf6\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Measure SF6: Temperature-Compensated Gas Density Monitors\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/#website\",\"url\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/\",\"name\":\"WIKA blog\",\"description\":\"Our blog offers many interesting articles on pressure, temperature, level, flow measurement calibration technology and provides insights into the WIKA Group.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/#\\\/schema\\\/person\\\/2a70a7718e6bfe7c6052a7702d4057c5\",\"name\":\"Leo Lopez\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/files\\\/2024\\\/02\\\/leolopez238-2-120x120.jpg\",\"url\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/files\\\/2024\\\/02\\\/leolopez238-2-120x120.jpg\",\"contentUrl\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/files\\\/2024\\\/02\\\/leolopez238-2-120x120.jpg\",\"caption\":\"Leo Lopez\"},\"description\":\"As a market segment manager for SF6 products in the Americas, I\u2019ve been responsible to grow our SF6 business to keep up with our 2025 vision. I find it fascinating when we accomplish many tasks such as market penetration for our SF6 handling equipment and SF6 transmitters. I love to travel and create new opportunities for WIKA.\",\"url\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/author\\\/llopez\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Measure SF6: 4 Types of Gas Density Monitors - WIKA blog","description":"WIKA offers a complete range of temperature-compensated gas density monitors to accurately measure sulfur hexafluoride (SF6) and other gases.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/knowhow\/temperature-compensated-gas-density-monitors-accurately-measures-sf6\/","og_locale":"en_US","og_type":"article","og_title":"Measure SF6: 4 Types of Gas Density Monitors - WIKA blog","og_description":"WIKA offers a complete range of temperature-compensated gas density monitors to accurately measure sulfur hexafluoride (SF6) and other gases.","og_url":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/knowhow\/temperature-compensated-gas-density-monitors-accurately-measures-sf6\/","og_site_name":"WIKA blog","og_image":[{"width":838,"height":471,"url":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/files\/2021\/03\/wika_hochspannung_istock_935697medium_cmyk_resized.jpg","type":"image\/jpeg"}],"author":"Leo Lopez","twitter_misc":{"Written by":"Leo Lopez","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/knowhow\/temperature-compensated-gas-density-monitors-accurately-measures-sf6\/#article","isPartOf":{"@id":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/knowhow\/temperature-compensated-gas-density-monitors-accurately-measures-sf6\/"},"author":{"name":"Leo Lopez","@id":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/#\/schema\/person\/2a70a7718e6bfe7c6052a7702d4057c5"},"headline":"Measure SF6: Temperature-Compensated Gas Density Monitors","datePublished":"2021-03-26T18:25:02+00:00","dateModified":"2025-05-23T13:15:58+00:00","mainEntityOfPage":{"@id":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/knowhow\/temperature-compensated-gas-density-monitors-accurately-measures-sf6\/"},"wordCount":693,"commentCount":0,"image":{"@id":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/knowhow\/temperature-compensated-gas-density-monitors-accurately-measures-sf6\/#primaryimage"},"thumbnailUrl":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/files\/2021\/03\/wika_hochspannung_istock_935697medium_cmyk_resized.jpg","keywords":["SF6"],"articleSection":["Know-how","SF6 Gas Solutions"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/knowhow\/temperature-compensated-gas-density-monitors-accurately-measures-sf6\/","url":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/knowhow\/temperature-compensated-gas-density-monitors-accurately-measures-sf6\/","name":"Measure SF6: 4 Types of Gas Density Monitors - WIKA blog","isPartOf":{"@id":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/knowhow\/temperature-compensated-gas-density-monitors-accurately-measures-sf6\/#primaryimage"},"image":{"@id":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/knowhow\/temperature-compensated-gas-density-monitors-accurately-measures-sf6\/#primaryimage"},"thumbnailUrl":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/files\/2021\/03\/wika_hochspannung_istock_935697medium_cmyk_resized.jpg","datePublished":"2021-03-26T18:25:02+00:00","dateModified":"2025-05-23T13:15:58+00:00","author":{"@id":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/#\/schema\/person\/2a70a7718e6bfe7c6052a7702d4057c5"},"description":"WIKA offers a complete range of temperature-compensated gas density monitors to accurately measure sulfur hexafluoride (SF6) and other gases.","breadcrumb":{"@id":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/knowhow\/temperature-compensated-gas-density-monitors-accurately-measures-sf6\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog-stage.wika.cloudpowered.services\/us\/knowhow\/temperature-compensated-gas-density-monitors-accurately-measures-sf6\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/knowhow\/temperature-compensated-gas-density-monitors-accurately-measures-sf6\/#primaryimage","url":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/files\/2021\/03\/wika_hochspannung_istock_935697medium_cmyk_resized.jpg","contentUrl":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/files\/2021\/03\/wika_hochspannung_istock_935697medium_cmyk_resized.jpg","width":838,"height":471,"caption":"WIKA offers a complete range of gas density monitors to accurately measure sulfur hexafluoride (SF6) and other gases."},{"@type":"BreadcrumbList","@id":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/knowhow\/temperature-compensated-gas-density-monitors-accurately-measures-sf6\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/"},{"@type":"ListItem","position":2,"name":"Measure SF6: Temperature-Compensated Gas Density Monitors"}]},{"@type":"WebSite","@id":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/#website","url":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/","name":"WIKA blog","description":"Our blog offers many interesting articles on pressure, temperature, level, flow measurement calibration technology and provides insights into the WIKA Group.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/#\/schema\/person\/2a70a7718e6bfe7c6052a7702d4057c5","name":"Leo Lopez","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/files\/2024\/02\/leolopez238-2-120x120.jpg","url":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/files\/2024\/02\/leolopez238-2-120x120.jpg","contentUrl":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/files\/2024\/02\/leolopez238-2-120x120.jpg","caption":"Leo Lopez"},"description":"As a market segment manager for SF6 products in the Americas, I\u2019ve been responsible to grow our SF6 business to keep up with our 2025 vision. I find it fascinating when we accomplish many tasks such as market penetration for our SF6 handling equipment and SF6 transmitters. I love to travel and create new opportunities for WIKA.","url":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/author\/llopez\/"}]}},"_links":{"self":[{"href":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/wp-json\/wp\/v2\/posts\/14194","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/wp-json\/wp\/v2\/users\/189"}],"replies":[{"embeddable":true,"href":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/wp-json\/wp\/v2\/comments?post=14194"}],"version-history":[{"count":15,"href":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/wp-json\/wp\/v2\/posts\/14194\/revisions"}],"predecessor-version":[{"id":18604,"href":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/wp-json\/wp\/v2\/posts\/14194\/revisions\/18604"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/wp-json\/wp\/v2\/media\/14203"}],"wp:attachment":[{"href":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/wp-json\/wp\/v2\/media?parent=14194"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/wp-json\/wp\/v2\/categories?post=14194"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/wp-json\/wp\/v2\/tags?post=14194"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}