{"id":1583,"date":"2016-12-15T16:54:44","date_gmt":"2016-12-15T21:54:44","guid":{"rendered":"http:\/\/blog-stage.wika.cloudpowered.services\/us\/\/?p=1583"},"modified":"2024-08-07T16:04:22","modified_gmt":"2024-08-07T21:04:22","slug":"gas-temperature-affect-gas-density-measurements","status":"publish","type":"post","link":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/products\/sf6-products\/gas-temperature-affect-gas-density-measurements\/","title":{"rendered":"How Changes in Gas Temperature Affect Gas Density Measurements"},"content":{"rendered":"<p>Circuit breakers, disconnectors, and switchgear in power transmission and distribution (T&amp;D) operations have been using <a href=\"https:\/\/www.wika.com\/en-us\/power_transmission_and_distribution_sf6.WIKA\" rel=\"external\" target=\"_blank\">sulfur hexafluoride (SF<sub>6<\/sub>)<\/a> as insulation for decades. To maintain the excellent thermal conductivity and dielectric strength of SF<sub>6<\/sub>, however, you must keep proper amounts of SF<sub>6<\/sub>, gas purity and minimize the amounts of humidity and byproducts inside the gas chamber. The wrong conditions can lead to malfunction of the equipment and can compromise the safety of the operation. Gas density evaluation is one of the best ways to assess leaks and changes in composition. Most operators nowadays monitor SF<sub>6<\/sub>-insulated equipment using gas density measuring instrumentation. To measure SF<sub>6 <\/sub>density, the instrumentation measures the actual pressure and temperature of the gas. Those pressure and temperature measurements are then used as input in an equation of state to obtain gas density. With the exact values of pressure and temperature, gas density can be accurately calculated. However, changes in gas temperature affect the pressure within the closed chamber, with higher temperatures leading to higher pressures. Consequently, the gas density calculated using temperature and pressure measurements is no longer accurate. Changes in gas temperature must be compensated for to restore accuracy.<\/p>\n<h2>Temperature compensation<\/h2>\n<p>Constant indication of variations in gas temperature allows compensating for their effects. Variations in temperature can be assessed through different methods:<\/p>\n<ul>\n<li>Bimetals translate temperature changes into changes in length using the expansion characteristics of different materials.<\/li>\n<li>Bellows measure the internal temperature directly using an external capillary temperature sensor.<\/li>\n<li>Electronic sensors measure temperature changes and give a temperature-compensated output.<\/li>\n<\/ul>\n<h2>All-in-one solution<\/h2>\n\n      <div class=\"wp-caption alignright\" style=\"max-width:148px;\"><a href=\"http:\/\/blog-stage.wika.cloudpowered.services\/us\/\/files\/2016\/11\/gdht-20.png\"><img decoding=\"async\" src=\"https:\/\/blog-stage.wika.cloudpowered.services\/us\/\/files\/2016\/11\/gdht-20-140x140.png\" alt=\"GDHT-20\" \/><\/a><p class=\"wp-caption-text\">The GDHT-20 is a compact, comprehensive system with digital output that allows continuous monitoring of all relevant gas condition parameters.<\/p><\/div>\n    \n<p>WIKA\u2019s <a href=\"https:\/\/www.wika.com\/en-us\/gdht_20.WIKA\" rel=\"external\" target=\"_blank\">GDHT-20<\/a> is a multi-sensor digital gas pressure, temperature, humidity, and density transmitter. It measures gas temperature, pressure, and humidity inside the SF<sub>6 <\/sub>chamber. Based on these gas temperature and pressure measurements, a powerful microprocessor calculates gas density using a complex virial equation. The GDHT-20 uses three of the electronic sensors to measure and compensate for variations in gas temperature: one near the pressure measurement sensor, one near the humidity sensor, and a third one on the main electronics of the instrument. As a result, even the smallest variations in gas temperature are taken into account, and correct values of the different parameters are input into the equation of state. The actual gas density is calculated accurately. A product of advanced technology and streamlined design, the GDHT-20 has been developed in response to today\u2019s market needs. It is a compact device, easy to implement in new and existing T&amp;D environments. It has excellent signal stability and electromagnetic compatibility (EMC) characteristics. The GDHT-20 is reliable, accurate, maintenance free, and does not require recalibration. It communicates via the MODBUS RTU protocol, accommodating up to 247 transmitters in one bus. The GDHT-20 is best in class for continuous online monitoring of conditions in SF<sub>6<\/sub>-insulated equipment and ideal for smart grid applications. <a href=\"https:\/\/www.wika.com\/en-us\/contact.WIKA\" rel=\"external\" target=\"_blank\">Call WIKA\u2019s experts today<\/a> to learn more about how to ensure the safety of your T&amp;D operations with accurate gas density measurements of your SF<sub>6<\/sub>-insulated equipment.<\/p>\n<p>Click <a href=\"https:\/\/app.salesfusion.com\/webapp\/#\/page-builder\/creator\/41\" rel=\"external\" target=\"_blank\">here<\/a> to download the white paper &#8220;GPU-2000: WIKA&#8217;s Optimal Solution for Comprehensive SF<sub>6 <\/sub>Gas Handling&#8221;<\/p>\n<figure><img decoding=\"async\" src=\"https:\/\/blog-stage.wika.cloudpowered.services\/us\/\/files\/2018\/04\/gpu-2000-388x218.png\" alt=\"WIKA\u2019s All-in-One Solution for SF6 Handling\" \/><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Circuit breakers, disconnectors, and switchgear in power transmission and distribution (T&amp;D) operations have been using sulfur hexafluoride (SF6) as insulation for decades. To maintain the excellent thermal conductivity and dielectric strength of SF6, however, you must keep proper amounts of SF6, gas purity and minimize the amounts of humidity and byproducts inside the gas chamber. [&hellip;]<\/p>\n","protected":false},"author":189,"featured_media":1587,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[674],"tags":[676,819,677,984],"class_list":["post-1583","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-sf6-products","tag-applications","tag-power-generation","tag-sf6","tag-transmission-distribution"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>How Changes in Gas Temperature Affect Gas Density Measurements - WIKA blog<\/title>\n<meta name=\"description\" content=\"Circuit breakers, disconnectors, and switchgear in power transmission and distribution (T&amp;D) operations have been using sulfur hexafluoride (SF6) as insulation for decades.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog-stage.wika.cloudpowered.services\/us\/products\/sf6-products\/gas-temperature-affect-gas-density-measurements\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How Changes in Gas Temperature Affect Gas Density Measurements - WIKA blog\" \/>\n<meta property=\"og:description\" content=\"Circuit breakers, disconnectors, and switchgear in power transmission and distribution (T&amp;D) operations have been using sulfur hexafluoride (SF6) as insulation for decades.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog-stage.wika.cloudpowered.services\/us\/products\/sf6-products\/gas-temperature-affect-gas-density-measurements\/\" \/>\n<meta property=\"og:site_name\" content=\"WIKA blog\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog-stage.wika.cloudpowered.services\/us\/files\/2016\/12\/sf6-monitoring1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"767\" \/>\n\t<meta property=\"og:image:height\" content=\"469\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Leo Lopez\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Leo Lopez\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/products\\\/sf6-products\\\/gas-temperature-affect-gas-density-measurements\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/products\\\/sf6-products\\\/gas-temperature-affect-gas-density-measurements\\\/\"},\"author\":{\"name\":\"Leo Lopez\",\"@id\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/#\\\/schema\\\/person\\\/2a70a7718e6bfe7c6052a7702d4057c5\"},\"headline\":\"How Changes in Gas Temperature Affect Gas Density Measurements\",\"datePublished\":\"2016-12-15T21:54:44+00:00\",\"dateModified\":\"2024-08-07T21:04:22+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/products\\\/sf6-products\\\/gas-temperature-affect-gas-density-measurements\\\/\"},\"wordCount\":552,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/products\\\/sf6-products\\\/gas-temperature-affect-gas-density-measurements\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/files\\\/2016\\\/12\\\/sf6-monitoring1.png\",\"keywords\":[\"applications\",\"power generation\",\"SF6\",\"Transmission &amp; Distribution\"],\"articleSection\":[\"SF6 Gas Solutions\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/products\\\/sf6-products\\\/gas-temperature-affect-gas-density-measurements\\\/\",\"url\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/products\\\/sf6-products\\\/gas-temperature-affect-gas-density-measurements\\\/\",\"name\":\"How Changes in Gas Temperature Affect Gas Density Measurements - WIKA blog\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/products\\\/sf6-products\\\/gas-temperature-affect-gas-density-measurements\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/products\\\/sf6-products\\\/gas-temperature-affect-gas-density-measurements\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/files\\\/2016\\\/12\\\/sf6-monitoring1.png\",\"datePublished\":\"2016-12-15T21:54:44+00:00\",\"dateModified\":\"2024-08-07T21:04:22+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/#\\\/schema\\\/person\\\/2a70a7718e6bfe7c6052a7702d4057c5\"},\"description\":\"Circuit breakers, disconnectors, and switchgear in power transmission and distribution (T&D) operations have been using sulfur hexafluoride (SF6) as insulation for decades.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/products\\\/sf6-products\\\/gas-temperature-affect-gas-density-measurements\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/products\\\/sf6-products\\\/gas-temperature-affect-gas-density-measurements\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/products\\\/sf6-products\\\/gas-temperature-affect-gas-density-measurements\\\/#primaryimage\",\"url\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/files\\\/2016\\\/12\\\/sf6-monitoring1.png\",\"contentUrl\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/files\\\/2016\\\/12\\\/sf6-monitoring1.png\",\"width\":767,\"height\":469},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/products\\\/sf6-products\\\/gas-temperature-affect-gas-density-measurements\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How Changes in Gas Temperature Affect Gas Density Measurements\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/#website\",\"url\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/\",\"name\":\"WIKA blog\",\"description\":\"Our blog offers many interesting articles on pressure, temperature, level, flow measurement calibration technology and provides insights into the WIKA Group.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/#\\\/schema\\\/person\\\/2a70a7718e6bfe7c6052a7702d4057c5\",\"name\":\"Leo Lopez\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/files\\\/2024\\\/02\\\/leolopez238-2-120x120.jpg\",\"url\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/files\\\/2024\\\/02\\\/leolopez238-2-120x120.jpg\",\"contentUrl\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/files\\\/2024\\\/02\\\/leolopez238-2-120x120.jpg\",\"caption\":\"Leo Lopez\"},\"description\":\"As a market segment manager for SF6 products in the Americas, I\u2019ve been responsible to grow our SF6 business to keep up with our 2025 vision. I find it fascinating when we accomplish many tasks such as market penetration for our SF6 handling equipment and SF6 transmitters. I love to travel and create new opportunities for WIKA.\",\"url\":\"https:\\\/\\\/blog-stage.wika.cloudpowered.services\\\/us\\\/author\\\/llopez\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How Changes in Gas Temperature Affect Gas Density Measurements - WIKA blog","description":"Circuit breakers, disconnectors, and switchgear in power transmission and distribution (T&D) operations have been using sulfur hexafluoride (SF6) as insulation for decades.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/products\/sf6-products\/gas-temperature-affect-gas-density-measurements\/","og_locale":"en_US","og_type":"article","og_title":"How Changes in Gas Temperature Affect Gas Density Measurements - WIKA blog","og_description":"Circuit breakers, disconnectors, and switchgear in power transmission and distribution (T&D) operations have been using sulfur hexafluoride (SF6) as insulation for decades.","og_url":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/products\/sf6-products\/gas-temperature-affect-gas-density-measurements\/","og_site_name":"WIKA blog","og_image":[{"width":767,"height":469,"url":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/files\/2016\/12\/sf6-monitoring1.png","type":"image\/png"}],"author":"Leo Lopez","twitter_misc":{"Written by":"Leo Lopez","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/products\/sf6-products\/gas-temperature-affect-gas-density-measurements\/#article","isPartOf":{"@id":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/products\/sf6-products\/gas-temperature-affect-gas-density-measurements\/"},"author":{"name":"Leo Lopez","@id":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/#\/schema\/person\/2a70a7718e6bfe7c6052a7702d4057c5"},"headline":"How Changes in Gas Temperature Affect Gas Density Measurements","datePublished":"2016-12-15T21:54:44+00:00","dateModified":"2024-08-07T21:04:22+00:00","mainEntityOfPage":{"@id":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/products\/sf6-products\/gas-temperature-affect-gas-density-measurements\/"},"wordCount":552,"commentCount":0,"image":{"@id":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/products\/sf6-products\/gas-temperature-affect-gas-density-measurements\/#primaryimage"},"thumbnailUrl":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/files\/2016\/12\/sf6-monitoring1.png","keywords":["applications","power generation","SF6","Transmission &amp; Distribution"],"articleSection":["SF6 Gas Solutions"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/products\/sf6-products\/gas-temperature-affect-gas-density-measurements\/","url":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/products\/sf6-products\/gas-temperature-affect-gas-density-measurements\/","name":"How Changes in Gas Temperature Affect Gas Density Measurements - WIKA blog","isPartOf":{"@id":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/products\/sf6-products\/gas-temperature-affect-gas-density-measurements\/#primaryimage"},"image":{"@id":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/products\/sf6-products\/gas-temperature-affect-gas-density-measurements\/#primaryimage"},"thumbnailUrl":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/files\/2016\/12\/sf6-monitoring1.png","datePublished":"2016-12-15T21:54:44+00:00","dateModified":"2024-08-07T21:04:22+00:00","author":{"@id":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/#\/schema\/person\/2a70a7718e6bfe7c6052a7702d4057c5"},"description":"Circuit breakers, disconnectors, and switchgear in power transmission and distribution (T&D) operations have been using sulfur hexafluoride (SF6) as insulation for decades.","breadcrumb":{"@id":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/products\/sf6-products\/gas-temperature-affect-gas-density-measurements\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog-stage.wika.cloudpowered.services\/us\/products\/sf6-products\/gas-temperature-affect-gas-density-measurements\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/products\/sf6-products\/gas-temperature-affect-gas-density-measurements\/#primaryimage","url":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/files\/2016\/12\/sf6-monitoring1.png","contentUrl":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/files\/2016\/12\/sf6-monitoring1.png","width":767,"height":469},{"@type":"BreadcrumbList","@id":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/products\/sf6-products\/gas-temperature-affect-gas-density-measurements\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/"},{"@type":"ListItem","position":2,"name":"How Changes in Gas Temperature Affect Gas Density Measurements"}]},{"@type":"WebSite","@id":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/#website","url":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/","name":"WIKA blog","description":"Our blog offers many interesting articles on pressure, temperature, level, flow measurement calibration technology and provides insights into the WIKA Group.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/#\/schema\/person\/2a70a7718e6bfe7c6052a7702d4057c5","name":"Leo Lopez","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/files\/2024\/02\/leolopez238-2-120x120.jpg","url":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/files\/2024\/02\/leolopez238-2-120x120.jpg","contentUrl":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/files\/2024\/02\/leolopez238-2-120x120.jpg","caption":"Leo Lopez"},"description":"As a market segment manager for SF6 products in the Americas, I\u2019ve been responsible to grow our SF6 business to keep up with our 2025 vision. I find it fascinating when we accomplish many tasks such as market penetration for our SF6 handling equipment and SF6 transmitters. I love to travel and create new opportunities for WIKA.","url":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/author\/llopez\/"}]}},"_links":{"self":[{"href":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/wp-json\/wp\/v2\/posts\/1583","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/wp-json\/wp\/v2\/users\/189"}],"replies":[{"embeddable":true,"href":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/wp-json\/wp\/v2\/comments?post=1583"}],"version-history":[{"count":8,"href":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/wp-json\/wp\/v2\/posts\/1583\/revisions"}],"predecessor-version":[{"id":16910,"href":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/wp-json\/wp\/v2\/posts\/1583\/revisions\/16910"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/wp-json\/wp\/v2\/media\/1587"}],"wp:attachment":[{"href":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/wp-json\/wp\/v2\/media?parent=1583"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/wp-json\/wp\/v2\/categories?post=1583"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog-stage.wika.cloudpowered.services\/us\/wp-json\/wp\/v2\/tags?post=1583"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}